C9606R Specification | |
Supervisor engines supported | C9600-SUP-1 |
Total number of slots | 6 |
Line-card slots | 4 |
Supervisor engine slots | 2 |
Dedicated supervisor engine slot numbers | 3 and 4 |
Maximum bandwidth scalability per line-card slot | 6.4 Tbps (Hardware ready) 2.4 Tbps (With C9600-SUP-1) |
Number of power supply bays | 4 |
Number of fan-tray bays | 1 |
Rack Units (RU) | 8 |
Power supplies supported | 2000W AC, 2000W DC |
Minimum number of power supplies | 2(Fully loaded 9606R chassis, Minimum 3 power supplies required if input voltage is 110V) |
Input voltage | AC: 90V to 264V, 47 to 63 Hz AC DC: -40V to -72V |
Operating temperature | -5° to 45° C (23° to 113° F) up to 6000 feet -5° to 40° C (23° to 104° F) up to 10,000 feet |
Storage temperature | -40° to 75° C (40° to 167° F) |
Relative humidity, operating and nonoperating, noncondensing | 10% to 95%, noncondensing |
Altitude | -60 to 3000 m (-197 to 9843 feet) |
Mean Time Between Failures (MTBF) (hours) | C9606R chassis: 4,113,900 C9606 fan tray: 452,570 |
Dimensions (H x W x D) | 35.43 x 44.2 x 40.9 cm 13.95 x 17.4 x 16.1 in. |