S5731-H48T4XC Specification | |
Fixed port | 48 x 10/100/1000Base-T ports, 4 x 10GE SFP+ ports |
Dimensions (H x W x D) | 43.6 mm x 442 mm x 420mm |
Chassis height | 1 U |
Chassis weight (including packaging) | 8.55 kg |
Extended slot | One extended slot, support 2 x 40GE, 8 x 10GE Base-T, 2 x 25GE SFP28 or 8 x 10GE SFP+ cards |
Power supply type | • 600 W AC (pluggable) • 150 W AC (pluggable) • 1000 W DC (pluggable) |
Rated voltage range | • AC input (600 W AC ): 100 V AC to 240 V AC, 50/60 Hz • AC input (150 W AC ): 100 V AC to 240 V AC, 50/60 Hz • DC input (1000 W DC): -48 VDC to -60 V DC |
Maximum voltage range | • AC input (150 W AC ): 90 V AC to 264 V AC, 47 Hz to 63 Hz • AC input (600 W AC ): 90 V AC to 290 V AC, 45 Hz to 65 Hz • High-voltage DC input (600 W AC): 190 V DC to 290 V DC (meeting 240 V high-voltage DC certification) • DC input (1000 W DC): -38.4 V DC to -72V DC |
Maximum power consumption | 124 W |
Noise | • Under normal temperature (sound power): 57.5dB (A) • Under high temperature (sound power): 70.9dB (A) • Under normal temperature (sound pressure): 47.5dB (A) |
Operating temperature | • 0-1800 m altitude: -5°C to 45°C • 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m. |
Storage temperature | -40°C to +70°C |
Relative humidity | 5% to 95% (non-condensing) |
Surge protection specification (service port) | Common mode: ±6 kV |
Surge protection specification (power port) | • AC power port: ±6 kV in differential mode, ±6 kV in common mode • DC power port: ±2 kV in differential mode, ±4 kV in common mode |
Heat dissipation | Air cooling heat dissipation, intelligent speed adjustment, and pluggable fans |