S5700-52P-PWR-LI-AC Specification | |
MAC address table | IEEE 802.1d compliance MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses MAC address entries: |
VLAN | 4K VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports 1:1 and N:1 VLAN Mapping SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series) |
Ring protection | RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover SEP ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) STP, RSTP, and MSTP BPDU protection, root protection, and loop protection BPDU Tunnel |
Reliability | Ethernet OAM (IEEE 802.3ah and 802.1ag) ITU-Y.1731 DLDP LACP E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series) BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series) |
MPLS features | MPLS L3VPN MPLS L2VPN(VPWS/VPLS) MPLS-TE MPLS QoS Notes: supported by S5710-EI, S5700-HI and S5710-HI |
IP routing | Static routing RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series) OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) |
IPv6 features | Neighbor Discovery (ND) Path MTU (PMTU) IPv6 ping, IPv6 tracert, and IPv6 Telnet ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type MLD v1/v2 snooping 6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series) |
Multicast | IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) |
Management and maintenance | Virtual cable test Port mirroring and RSPAN (remote port mirroring) Remote configuration and maintenance using Telnet SNMP v1/v2c/v3 RMON Web NMS HGMP System logs and alarms of different levels 802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI) Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI(except battery LAN switches) NetStream (supported by the S5710-EI, S5700-HI and S5710-HI) sFlow(supported by the S5700(S)-LI/S5700-EI/S5700-HI series) |
Interoperability | Supports VBST (Compatible with PVST/PVST+/RPVST) Supports LNP (Similar to DTP) Supports VCMP (Similar to VTP) |
Operating environment | Operating temperature: 0℃–50℃ Relative humidity: 10%–90% (non-condensing) |
Input voltage | AC: Rated voltage range: 100 V to 240 V AC, 50/60 Hz Maximum voltage range: 90 V to 264 V AC, 47/63 Hz DC: Rated voltage range: –48 V to –60 V, DC Maximum voltage range: –36 V to –72 V DC Note: PoE-support switches do not use DC power supplies. |