S2730S-S8FT4S-A Specification | |
Item | Specification |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 250.0 mm x 180.0 mm (1.72 in. x 9.84 in. x 7.1 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 250.0 mm x 187.0 mm (1.72 in. x 9.84 in. x 7.36 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 370.0 mm x 380.0 mm (3.54 in. x 14.57 in. x 14.96 in.) |
Chassis height [U] | 1 U |
Typical power consumption [W] | 21.2 W |
Typical heat dissipation [BTU/hour] | 72.34 BTU/hour |
Maximum power consumption [W] | 26.3 W |
Maximum heat dissipation [BTU/hour] | 89.74 BTU/hour |
MTBF [year] | 71.82 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 43 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 31.5 dB(A) |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 1 |
Redundant power supply | Not supported |
Short-term operating temperature [°C(°F)] | Not supported |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | AC built-in |
Rated input voltage [V] | AC input: 100 V AC to 240 V AC, 50/60 Hz |
Input voltage range [V] | AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz |
Maximum input current [A] | 0.8 A |
Memory | 512 MB |
Flash memory | 512 MB |
Console port | RJ45 |
Eth Management port | Not supported |
USB | Not supported |
RTC | Not supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] | ±6 kV in differential mode, ±6 kV in common mode |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left and front, air exhaustion from right |
PoE | Not supported |