S5735-L32ST4X-A1 Specification | |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.) |
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) | |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) |
Chassis height [U] | 1 U |
Typical power consumption [W] | 53.2 W |
Typical heat dissipation [BTU/hour] | 181.52 BTU/hour |
Maximum power consumption [W] | 66.8 W |
Maximum heat dissipation [BTU/hour] | 227.93 BTU/hour |
MTBF [year] | 58.44 year |
MTTR [hour] | 2 hour |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 2 |
Redundant power supply | Not supported |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: | |
The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year. | |
The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year. | |
The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year. | |
The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. | |
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. | |
Power supply mode | AC built-in |
Rated input voltage [V] | AC input: 100 V AC to 240 V AC, 50/60 Hz |
High-Voltage DC input: 240 V DC | |
Input voltage range [V] | AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz |
High-Voltage DC input: 190 V DC to 290 V DC | |
Maximum input current [A] | 2:00 AM |
Memory | 512 MB |
Flash memory | 512 MB |
Console port | RJ45 |
Eth Management port | Not supported |
USB | Supported |
RTC | Not supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] | ±6 kV in differential mode, ±6 kV in common mode |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left and front, air exhaustion from right |
PoE | Not supported |